{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2023-46862","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","dateUpdated":"2026-10-15T00:04:53.322Z","dateReserved":"2023-10-29T00:00:00.000Z","datePublished":"2023-10-29T00:00:00.000Z"},"containers":{"cna":{"providerMetadata":{"orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre","dateUpdated":"2024-01-11T21:06:27.982Z"},"descriptions":[{"lang":"en","value":"An issue was discovered in the Linux kernel through 6.5.9. During a race with SQ thread exit, an io_uring/fdinfo.c io_uring_show_fdinfo NULL pointer dereference can occur."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://github.com/torvalds/linux/commit/7644b1a1c9a7ae8ab99175989bfc8676055edb46"},{"url":"https://bugzilla.kernel.org/show_bug.cgi?id=218032#c4"},{"name":"[debian-lts-announce] 20240111 [SECURITY] [DLA 3711-1] linux-5.10 security update","tags":["mailing-list"],"url":"https://lists.debian.org/debian-lts-announce/2024/01/msg00005.html"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T20:53:21.892Z"},"title":"CVE Program Container","references":[{"url":"https://github.com/torvalds/linux/commit/7644b1a1c9a7ae8ab99175989bfc8676055edb46","tags":["x_transferred"]},{"url":"https://bugzilla.kernel.org/show_bug.cgi?id=218032#c4","tags":["x_transferred"]},{"name":"[debian-lts-announce] 20240111 [SECURITY] [DLA 3711-1] linux-5.10 security update","tags":["mailing-list","x_transferred"],"url":"https://lists.debian.org/debian-lts-announce/2024/01/msg00005.html"}]},{"x_adpType":"supplier","providerMetadata":{"orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP","dateUpdated":"2026-10-15T00:04:53.322Z"},"affected":[{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html"}]}]}}