{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-10945","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","dateReserved":"2024-11-06T20:19:56.382Z","datePublished":"2024-11-12T17:06:44.105Z","dateUpdated":"2024-11-13T17:39:55.391Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"FactoryTalk Updater","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"<4.20.00"}]}],"datePublic":"2024-11-12T14:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A Local Privilege Escalation vulnerability exists in the affected product. The vulnerability requires a local, low privileged threat actor to replace certain files during update and exists due to a failure to perform proper security checks before installation."}],"value":"A Local Privilege Escalation vulnerability exists in the affected product. The vulnerability requires a local, low privileged threat actor to replace certain files during update and exists due to a failure to perform proper security checks before installation."}],"impacts":[{"capecId":"CAPEC-233","descriptions":[{"lang":"en","value":"CAPEC-233 Privilege Escalation"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":7,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-754","description":"CWE-754 Improper Check for Unusual or Exceptional Conditions","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2024-11-12T17:06:44.105Z"},"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1710.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Upgrade to V4.20.00\n\n<br>"}],"value":"Upgrade to V4.20.00"}],"source":{"discovery":"INTERNAL"},"title":"FactoryTalk® Updater Local Privilege Escalation","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-10945","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2024-11-13T17:34:52.169747Z"}}}],"affected":[{"cpes":["cpe:2.3:a:rockwellautomation:factorytalk_updater:*:*:*:*:*:*:*:*"],"vendor":"rockwellautomation","product":"factorytalk_updater","versions":[{"status":"affected","version":"4.00.00","versionType":"custom","lessThanOrEqual":"4.20.00"}],"defaultStatus":"unknown"}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-13T17:39:55.391Z"}}]}}