{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-1628","assignerOrgId":"171caf72-b841-4e04-a68e-93493aff2b94","state":"PUBLISHED","assignerShortName":"GEHC","dateReserved":"2024-02-19T15:23:20.113Z","datePublished":"2024-05-14T16:04:57.780Z","dateUpdated":"2024-08-01T18:48:21.580Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Venue","vendor":"GE HealthCare","versions":[{"status":"affected","version":"R1"},{"status":"affected","version":"R2"},{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.3","status":"affected","version":"R4","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Venue Go","vendor":"GE HealthCare","versions":[{"status":"affected","version":"R2"},{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.3","status":"affected","version":"R4","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Venue Fit","vendor":"GE HealthCare","versions":[{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.3","status":"affected","version":"R4","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"LOGIQ e","vendor":"GE HealthCare","versions":[{"lessThanOrEqual":"R9.1.4","status":"affected","version":"R7","versionType":"custom"},{"lessThanOrEqual":"R10.1.3","status":"affected","version":"R8","versionType":"custom"},{"lessThanOrEqual":"R11.0.3","status":"affected","version":"R9","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"LOGIQ He","vendor":"GE HealthCare","versions":[{"lessThanOrEqual":"R9.3.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Vivid E","vendor":"GE HealthCare","versions":[{"lessThan":"206","status":"affected","version":"E95","versionType":"custom"},{"lessThan":"206","status":"affected","version":"E90","versionType":"custom"},{"lessThan":"206","status":"affected","version":"E80","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Vivid S","vendor":"GE HealthCare","versions":[{"lessThan":"206","status":"affected","version":"70N","versionType":"custom"},{"lessThan":"206","status":"affected","version":"60N","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Vivid T","vendor":"GE HealthCare","versions":[{"lessThan":"206","status":"affected","version":"T8","versionType":"custom"},{"lessThan":"206","status":"affected","version":"T9","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Vivid iq","vendor":"GE HealthCare","versions":[{"lessThan":"206","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Voluson Expert 16","vendor":"GE HealthCare","versions":[{"status":"affected","version":"0"},{"lessThan":"Ext1","status":"affected","version":"BT24","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Voluson Expert 18","vendor":"GE HealthCare","versions":[{"status":"affected","version":"0"},{"lessThan":"Ext1","status":"affected","version":"BT24","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Voluson Expert 22","vendor":"GE HealthCare","versions":[{"status":"affected","version":"0"},{"lessThan":"Ext1","status":"affected","version":"BT24","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Voluson SWIFT","vendor":"GE HealthCare","versions":[{"status":"affected","version":"0"},{"status":"affected","version":"BT24"}]},{"defaultStatus":"unaffected","product":"Invenia ABUS 2.0","vendor":"GE HealthCare","versions":[{"lessThanOrEqual":"2.2.7","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"LOGIQ E10","vendor":"GE HealthCare","versions":[{"lessThan":"R3.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"LOGIQ E10s","vendor":"GE HealthCare","versions":[{"lessThan":"R3.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"LOGIQ Fortis","vendor":"GE HealthCare","versions":[{"lessThan":"R3.2.0","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"OS command injection vulnerabilities in GE HealthCare ultrasound devices"}],"value":"OS command injection vulnerabilities in GE HealthCare ultrasound devices"}],"impacts":[{"capecId":"CAPEC-6","descriptions":[{"lang":"en","value":"CAPEC-6 Argument Injection"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.4,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"171caf72-b841-4e04-a68e-93493aff2b94","shortName":"GEHC","dateUpdated":"2024-05-14T16:04:57.780Z"},"references":[{"url":"https://securityupdate.gehealthcare.com/"}],"source":{"discovery":"EXTERNAL"},"title":"OS command injection vulnerabilities in GE HealthCare ultrasound devices","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-1628","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2024-05-16T16:10:00.517201Z"}}}],"affected":[{"cpes":["cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*"],"vendor":"ge_healthcare","product":"venue","versions":[{"status":"affected","version":"multiple versions"}],"defaultStatus":"unknown"},{"cpes":["cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*"],"vendor":"ge_healthcare","product":"vivid","versions":[{"status":"affected","version":"multiple versions"}],"defaultStatus":"unknown"},{"cpes":["cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*"],"vendor":"ge_healthcare","product":"voluson","versions":[{"status":"affected","version":"multiple versions"}],"defaultStatus":"unknown"},{"cpes":["cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*"],"vendor":"ge_healthcare","product":"logiq","versions":[{"status":"affected","version":"multiple versions"}],"defaultStatus":"unknown"}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T18:01:30.939Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T18:48:21.580Z"},"title":"CVE Program Container","references":[{"url":"https://securityupdate.gehealthcare.com/","tags":["x_transferred"]}]}]}}