{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-49397","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2024-10-14T22:56:08.990Z","datePublished":"2024-10-17T16:15:14.508Z","dateUpdated":"2024-10-17T17:51:47.925Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"M-Bus Metering Gateway CMe3100","vendor":"Elvaco","versions":[{"status":"affected","version":"1.12.1"}]}],"credits":[{"lang":"en","type":"finder","value":"Tomer Goldschmidt of Claroty Research - Team82 reported these vulnerabilities to CISA."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p></p>\n\n<p>The affected product is vulnerable to a cross-site scripting attack which may allow an attacker to bypass authentication and takeover admin accounts.</p><br>\n\n<br>"}],"value":"The affected product is vulnerable to a cross-site scripting attack which may allow an attacker to bypass authentication and takeover admin accounts."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"HIGH","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.2,"baseSeverity":"CRITICAL","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2024-10-17T16:15:14.508Z"},"references":[{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-291-01"}],"source":{"discovery":"UNKNOWN"},"title":"Cross-site Scripting in Elvaco M-Bus Metering Gateway CMe3100","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"elvaco","product":"cme3100_firmware","cpes":["cpe:2.3:o:elvaco:cme3100_firmware:1.12.1:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"1.12.1","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-17T16:50:21.310673Z","id":"CVE-2024-49397","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-10-17T17:51:47.925Z"}}]}}