{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-5679","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2024-06-06T12:06:38.709Z","datePublished":"2024-07-11T08:18:23.853Z","dateUpdated":"2024-08-01T21:18:06.706Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure Foxboro DCS Core Control Services","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions 9.8 and prior"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nCWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or\nkernel memory leak when a malicious actor with local user access crafts a script/program using\nan IOCTL call in the Foxboro.sys driver.\n\n"}],"value":"CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or\nkernel memory leak when a malicious actor with local user access crafts a script/program using\nan IOCTL call in the Foxboro.sys driver."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.1,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"CWE-787 Out-of-bounds Write","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2024-07-11T08:18:23.853Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-02.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-11T14:05:59.571941Z","id":"CVE-2024-5679","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-11T18:01:50.665Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T21:18:06.706Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-02.pdf","tags":["x_transferred"]}]}]}}