{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-0631","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","dateReserved":"2025-01-21T21:21:05.171Z","datePublished":"2025-01-28T18:27:32.084Z","dateUpdated":"2025-02-06T21:26:17.072Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerFlex 755","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"<=16.002.279"}]}],"datePublic":"2025-01-28T14:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p><span style=\"background-color: var(--wht);\">A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text.</span><br></p>"}],"value":"A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text."}],"impacts":[{"capecId":"CAPEC-157","descriptions":[{"lang":"en","value":"CAPEC-157 Sniffing Attacks"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-319","description":"CWE-319 Cleartext Transmission of Sensitive Information","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2025-01-28T18:27:32.084Z"},"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1717.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Upgrade to v20.3.407"}],"value":"Upgrade to v20.3.407"}],"source":{"discovery":"INTERNAL"},"title":"PowerFlex® 755 Credential Exposure Vulnerability","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-01-28T18:57:46.274914Z","id":"CVE-2025-0631","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-06T21:26:17.072Z"}}]}}