{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-14097","assignerOrgId":"46b595e9-1acc-41cb-9398-adaf98d37a9b","state":"PUBLISHED","assignerShortName":"Radiometer","dateReserved":"2025-12-05T10:50:03.683Z","datePublished":"2025-12-17T12:36:03.779Z","dateUpdated":"2025-12-17T14:41:13.252Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"ABL90 FLEX and ABL90 FLEX PLUS Analyzers","vendor":"Radiometer Medical Aps","versions":[{"status":"affected","version":"Application software versions < 3.5MR11 with Windows 7, Windows XP operating systems","versionType":"ABL90 DMS (Data Management system)"},{"status":"unaffected","version":"Application software versions >= 3.5MR11 with Windows 10 operating system","versionType":"ABL90 DMS (Data Management system)"}]},{"defaultStatus":"unaffected","product":"ABL800 BASIC and ABL800 FLEX Analyzers","vendor":"Radiometer Medical Aps","versions":[{"status":"affected","version":"Application software versions < 6.20MR2 with Windows 7, Windows XP operating systems","versionType":"ABL800 DMS(Data Management System)"},{"status":"unaffected","version":"Application software versions >= 6.20MR2 with Windows 10 operating system","versionType":"ABL800 DMS(Data Management System)"}]},{"defaultStatus":"unaffected","product":"AQT90 FLEX Analyzers","vendor":"Radiometer Medical Aps","versions":[{"status":"affected","version":"Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems","versionType":"AQT90 DMS (Data Management System)"},{"status":"unaffected","version":"Application software versions >= 8.13 MR2 with Windows 10 operating system","versionType":"AQT90 DMS (Data Management System)"}]}],"configurations":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Affected application software version is in use AND Remote support feature is enabled in the Analyzer.\n\n<br>"}],"value":"Affected application software version is in use AND Remote support feature is enabled in the Analyzer."}],"credits":[{"lang":"en","type":"reporter","value":"Florian Hauser and Fabian Weber from CODE WHITE GmbH"}],"datePublic":"2025-12-17T12:35:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means.  The issue is caused by a weakness in the analyzer’s application software.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Other related CVE's are CVE-2025-14095 &amp; CVE-2025-14096.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <span style=\"background-color: rgb(255, 255, 255);\">Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.</span>\n\n<br><br>Required Configuration for Exposure:&nbsp;<span style=\"background-color: rgb(255, 255, 255);\">Affected application software version is in use and remote support feature is enabled in the analyzer.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; </span>Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Permanent solution:<br>Customers should ensure the following:<br>•  The network is secure, and access follows best practices.<br>Local Radiometer representatives will contact all affected customers to discuss a permanent solution.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<br>Exploit Status:<br>\n\n<span style=\"background-color: rgb(255, 255, 255);\">Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.</span>\n\n<br>"}],"value":"A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means.  The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\nRequired Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution:\nCustomers should ensure the following:\n•  The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                     \nExploit Status:\n\n\nResearchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication."}],"exploits":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.\n\n<br>"}],"value":"Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication."}],"impacts":[{"capecId":"CAPEC-555","descriptions":[{"lang":"en","value":"CAPEC-555: Remote Services with Stolen Credentials"}]},{"capecId":"CAPEC-653","descriptions":[{"lang":"en","value":"CAPEC-653: Use of Known Operating System Credentials"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-287","description":"CWE-287: Improper Authentication","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"46b595e9-1acc-41cb-9398-adaf98d37a9b","shortName":"Radiometer","dateUpdated":"2025-12-17T13:14:55.334Z"},"references":[{"url":"https://www.radiometer.com/myradiometer"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Customers should ensure the following:<br>•  The network is secure, and access follows best practices.<br>Local Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\n\n\n<br>"}],"value":"Customers should ensure the following:\n•  The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution."}],"source":{"discovery":"EXTERNAL"},"timeline":[{"lang":"en","time":"2025-12-17T12:35:00.000Z","value":"CVE Published"}],"title":"Remote Code Execution Vulnerability in Radiometer Products","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"If the network is not considered secure, please remove the analyzer from the network."}],"value":"If the network is not considered secure, please remove the analyzer from the network."}],"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-12-17T14:40:30.048229Z","id":"CVE-2025-14097","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-12-17T14:41:13.252Z"}}]}}