{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-34044","assignerOrgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","state":"PUBLISHED","assignerShortName":"VulnCheck","dateReserved":"2025-04-15T19:15:22.547Z","datePublished":"2025-06-26T15:51:30.957Z","dateUpdated":"2025-11-17T21:15:30.068Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","modules":["Web Management Interface (confirm.php interface)","t parameter"],"product":"WIFISKY 7-layer flow control router","vendor":"Shenzhen Lingkong Technology","versions":[{"status":"affected","version":"0"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A remote command injection vulnerability exists in the <code>confirm.php</code> interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands.&nbsp;Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC."}],"value":"A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC."}],"impacts":[{"capecId":"CAPEC-88","descriptions":[{"lang":"en","value":"CAPEC-88 OS Command Injection"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.4,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","shortName":"VulnCheck","dateUpdated":"2025-11-17T21:15:30.068Z"},"references":[{"tags":["product"],"url":"http://www.szwifisky.com/"},{"tags":["third-party-advisory"],"url":"https://www.cnvd.org.cn/flaw/show/CNVD-2021-45363"},{"tags":["third-party-advisory"],"url":"https://s4e.io/tools/wifisky-7-layer-flow-control-router-remote-code-execution"},{"tags":["third-party-advisory"],"url":"https://www.variotdbs.pl/vuln/VAR-202107-1715/"},{"tags":["third-party-advisory"],"url":"https://vulncheck.com/advisories/wifisky-flow-control-router-rce"},{"url":"https://github.com/projectdiscovery/nuclei-templates/blob/main/http/vulnerabilities/other/wifisky7-rce.yaml"}],"source":{"discovery":"UNKNOWN"},"tags":["x_known-exploited-vulnerability"],"title":"WIFISKY 7-Layer Flow Control Router Remote Command Execution","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-06-27T13:34:40.710185Z","id":"CVE-2025-34044","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-06-27T13:34:55.104Z"}}]}}