{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-41709","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","state":"PUBLISHED","assignerShortName":"CERTVDE","dateReserved":"2025-04-16T11:17:48.311Z","datePublished":"2026-03-10T08:26:14.936Z","dateUpdated":"2026-03-18T08:16:28.698Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"UMG 96RM-E 24V(5222063)","vendor":"Janitza","versions":[{"lessThanOrEqual":"3.13","status":"affected","version":"0.0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"UMG 96RM-E 230V(5222062)","vendor":"Janitza","versions":[{"lessThanOrEqual":"3.13","status":"affected","version":"0.0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"ENERGY METER 750-230 (2540910000)","vendor":"Weidmueller","versions":[{"lessThanOrEqual":"3.13","status":"affected","version":"0.0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"ENERGY METER 750-24 (2540900000)","vendor":"Weidmueller","versions":[{"lessThanOrEqual":"3.13","status":"affected","version":"0.0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"reporter","user":"00000000-0000-4000-9000-000000000000","value":"Deutsche Telekom Security (DT Security)"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">An unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device.</span><br>"}],"value":"An unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE","dateUpdated":"2026-03-18T08:16:28.698Z"},"references":[{"tags":["vendor-advisory"],"url":"https://certvde.com/en/advisories/VDE-2025-079/"},{"tags":["vendor-advisory"],"url":"https://certvde.com/en/advisories/VDE-2025-096/"},{"tags":["vendor-advisory"],"url":"https://janitza.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-079.json"},{"tags":["vendor-advisory"],"url":"https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-096.json"}],"source":{"discovery":"UNKNOWN"},"title":"Command injection in power analyzer via Modbus-TCP and Modbus-RTU","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-03-10T15:58:49.458010Z","id":"CVE-2025-41709","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-03-10T16:51:53.333Z"}}]}}