{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-41729","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","state":"PUBLISHED","assignerShortName":"CERTVDE","dateReserved":"2025-04-16T11:17:48.319Z","datePublished":"2025-11-24T11:27:15.058Z","dateUpdated":"2025-11-24T13:16:00.535Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"UMG 96-PA","vendor":"Janitza","versions":[{"lessThan":"3.54","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"UMG 96-PA-MID+","vendor":"Janitza","versions":[{"lessThan":"3.54","status":"affected","version":"0.0.0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Milence - Commercial Vehicle Charging Europe B.V."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An unauthenticated remote attacker can send a specially crafted Modbus read command to the device which leads to a denial of service.<br>"}],"value":"An unauthenticated remote attacker can send a specially crafted Modbus read command to the device which leads to a denial of service."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1287","description":"CWE-1287 Improper Validation of Specified Type of Input","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE","dateUpdated":"2025-11-24T11:27:15.058Z"},"references":[{"url":"https://certvde.com/de/advisories/VDE-2025-094"}],"source":{"advisory":"VDE-2025-094","defect":["CERT@VDE#641878"],"discovery":"UNKNOWN"},"title":"DoS via Modbus Read Command","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-11-24T13:15:50.089873Z","id":"CVE-2025-41729","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-11-24T13:16:00.535Z"}}]}}