{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-4902","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2025-05-17T13:06:13.410Z","datePublished":"2025-05-19T00:00:08.280Z","dateUpdated":"2025-05-19T14:00:13.845Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2025-05-19T00:00:08.280Z"},"title":"D-Link DI-7003GV2 versionupdate.data sub_48F4F0 information disclosure","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-200","lang":"en","description":"Information Disclosure"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-284","lang":"en","description":"Improper Access Controls"}]}],"affected":[{"vendor":"D-Link","product":"DI-7003GV2","versions":[{"version":"24.04.18D1 R(68125)","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability, which was classified as problematic, has been found in D-Link DI-7003GV2 24.04.18D1 R(68125). Affected by this issue is the function sub_48F4F0 of the file /H5/versionupdate.data. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."},{"lang":"de","value":"Eine problematische Schwachstelle wurde in D-Link DI-7003GV2 24.04.18D1 R(68125) entdeckt. Betroffen davon ist die Funktion sub_48F4F0 der Datei /H5/versionupdate.data. Mittels Manipulieren mit unbekannten Daten kann eine information disclosure-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":6.9,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","baseSeverity":"MEDIUM"}},{"cvssV3_1":{"version":"3.1","baseScore":5.3,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseSeverity":"MEDIUM"}},{"cvssV3_0":{"version":"3.0","baseScore":5.3,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseSeverity":"MEDIUM"}},{"cvssV2_0":{"version":"2.0","baseScore":5,"vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N"}}],"timeline":[{"time":"2025-05-17T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2025-05-17T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2025-05-17T15:11:26.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"153528990 (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.309458","name":"VDB-309458 | D-Link DI-7003GV2 versionupdate.data sub_48F4F0 information disclosure","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.309458","name":"VDB-309458 | CTI Indicators (IOB, IOC, TTP, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.578050","name":"Submit #578050 | D-Link DI-7003GV2 24.04.18D1 R(68125) Exposure of Sensitive System Information to an Unauthorized Cont","tags":["third-party-advisory"]},{"url":"https://github.com/at0de/my_vulns/blob/main/Dlink/Di-7003GV2/versionupdate.md","tags":["exploit","patch"]},{"url":"https://www.dlink.com/","tags":["product"]}]},"adp":[{"references":[{"url":"https://github.com/at0de/my_vulns/blob/main/Dlink/Di-7003GV2/versionupdate.md","tags":["exploit"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-05-19T14:00:08.954976Z","id":"CVE-2025-4902","options":[{"Exploitation":"poc"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-05-19T14:00:13.845Z"}}]}}