{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-52578","assignerOrgId":"0c426f27-3ee1-4eff-be88-288d5a1822bc","state":"PUBLISHED","assignerShortName":"Gallagher","dateReserved":"2025-11-11T04:00:46.463Z","datePublished":"2025-11-18T03:26:20.887Z","dateUpdated":"2025-11-19T16:49:32.455Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"High Sec End of Line Module","vendor":"Gallagher","versions":[{"lessThanOrEqual":"9.00","status":"affected","version":"0","versionType":"custom"},{"lessThan":"vCR9.30.251028a","status":"affected","version":"9.30","versionType":"custom"},{"lessThan":"vCR9.20.251028a","status":"affected","version":"9.20","versionType":"custom"},{"lessThan":"vCR9.10.251028a","status":"affected","version":"9.10","versionType":"custom"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM</span><strong>&nbsp;</strong>may&nbsp;<span style=\"background-color: rgb(255, 255, 255);\">allow a sophisticated attacker with physical access, to compromise internal device communications.</span>\n\n<p>This issue affects Command Centre Server: \n\n9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)),&nbsp;all versions of 9.00 and prior.\n\n</p>"}],"value":"Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM may allow a sophisticated attacker with physical access, to compromise internal device communications.\n\nThis issue affects Command Centre Server: \n\n9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)), all versions of 9.00 and prior."}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"PHYSICAL","availabilityImpact":"NONE","baseScore":5.7,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-335","description":"CWE-335 Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"0c426f27-3ee1-4eff-be88-288d5a1822bc","shortName":"Gallagher","dateUpdated":"2025-11-18T03:26:20.887Z"},"references":[{"url":"https://security.gallagher.com/en-NZ/Security-Advisories/CVE-2025-52578"}],"source":{"discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-11-18T15:04:03.417918Z","id":"CVE-2025-52578","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-11-19T16:49:32.455Z"}}]}}