{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-54497","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2025-08-06T16:32:41.300Z","datePublished":"2025-09-18T21:24:05.023Z","dateUpdated":"2025-09-19T13:12:37.793Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"In-Sight 2000 series","vendor":"Cognex","versions":[{"lessThanOrEqual":"6.5.1","status":"affected","version":"5.x","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"In-Sight 7000 series","vendor":"Cognex","versions":[{"lessThanOrEqual":"6.5.1","status":"affected","version":"5.x","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"In-Sight 8000 series","vendor":"Cognex","versions":[{"lessThanOrEqual":"6.5.1","status":"affected","version":"5.x","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"In-Sight 9000 series","vendor":"Cognex","versions":[{"lessThanOrEqual":"6.5.1","status":"affected","version":"5.x","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"In-Sight Explorer","vendor":"Cognex","versions":[{"lessThanOrEqual":"6.5.1","status":"affected","version":"5.x","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service \non port 23 to allow management operations such as firmware upgrades and \ndevice reboots, which require authentication. A user with protected \nprivileges can successfully invoke the SetSerialPort functionality to \nmodify relevant device properties (such as serial interface settings), \ncontradicting the security model proposed in the user manual."}],"value":"Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service \non port 23 to allow management operations such as firmware upgrades and \ndevice reboots, which require authentication. A user with protected \nprivileges can successfully invoke the SetSerialPort functionality to \nmodify relevant device properties (such as serial interface settings), \ncontradicting the security model proposed in the user manual."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":7.2,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-732","description":"CWE-732","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2025-09-18T21:24:05.023Z"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"}],"source":{"advisory":"ICSA-25-261-06","discovery":"EXTERNAL"},"title":"Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n<br>"}],"value":"Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-09-19T13:12:33.199419Z","id":"CVE-2025-54497","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-09-19T13:12:37.793Z"}}]}}