{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-58083","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2025-11-06T20:44:49.352Z","datePublished":"2025-11-14T23:24:54.274Z","dateUpdated":"2025-11-17T14:35:13.251Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Lynx+ Gateway","vendor":"General Industrial Controls","versions":[{"status":"affected","version":"Version R08"},{"status":"affected","version":"Version V03"},{"status":"affected","version":"Version V05"},{"status":"affected","version":"Version V18"}]}],"credits":[{"lang":"en","type":"finder","value":"Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"General Industrial Controls Lynx+ Gateway&nbsp;\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."}],"value":"General Industrial Controls Lynx+ Gateway \n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":10,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.2,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:H/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2025-11-14T23:24:54.274Z"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"}],"source":{"advisory":"ICSA-25-317-08","discovery":"EXTERNAL"},"title":"General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"General Industrial Controls (GIC) did not respond to CISA's attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to <a target=\"_blank\" rel=\"nofollow\">GIC</a> for more information.\n\n<br>"}],"value":"General Industrial Controls (GIC) did not respond to CISA's attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."}],"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-11-17T14:34:42.570290Z","id":"CVE-2025-58083","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-11-17T14:35:13.251Z"}}]}}