{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-58428","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2025-09-23T19:56:47.992Z","datePublished":"2025-10-23T19:49:23.232Z","dateUpdated":"2025-10-23T20:29:27.332Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"TLS4B Automatic Tank Gauge System","vendor":"Veeder-Root","versions":[{"lessThan":"11.A","status":"affected","version":"0","versionType":"custom"},{"status":"unaffected","version":"11.A"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:veeder-root:tls4b_automatic_tank_gauge_system:*:*:*:*:*:*:*:*","versionEndExcluding":"11.a","versionStartIncluding":"0","vulnerable":true},{"criteria":"cpe:2.3:a:veeder-root:tls4b_automatic_tank_gauge_system:11.a:*:*:*:*:*:*:*","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"reporter","value":"Pedro Umbelino of Bitsight reported these vulnerabilities to CISA."}],"datePublic":"2025-10-23T17:51:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The TLS4B ATG system's SOAP-based interface is vulnerable due to its accessibility through the web services handler. This vulnerability enables remote attackers with valid credentials to execute system-level commands on the underlying Linux system. This could allow the attacker to achieve remote command execution, full shell access, and potential lateral movement within the network."}],"value":"The TLS4B ATG system's SOAP-based interface is vulnerable due to its accessibility through the web services handler. This vulnerability enables remote attackers with valid credentials to execute system-level commands on the underlying Linux system. This could allow the attacker to achieve remote command execution, full shell access, and potential lateral movement within the network."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.4,"baseSeverity":"CRITICAL","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.9,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-77","description":"CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2025-10-23T19:49:23.232Z"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-296-03"},{"url":"https://www.veeder.com/us/software-downloads"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-296-03.json"},{"url":"https://www.veeder.com/us/network-security-reminder"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Veeder-Root recommends users upgrade the TLS4B to Version 11.A.<br>\n\n<p>Veeder-Root advises that their ASCs review and implement these best practices for network security with their users, when installing a new console or setting up a network port.</p><p>Contact Veeder-Root Technical Support at +1.800.323.1799 for additional help or questions.</p>"}],"value":"Veeder-Root recommends users upgrade the TLS4B to Version 11.A.\n\n\nVeeder-Root advises that their ASCs review and implement these best practices for network security with their users, when installing a new console or setting up a network port.\n\nContact Veeder-Root Technical Support at +1.800.323.1799 for additional help or questions."}],"source":{"advisory":"ICSA-25-296-03","discovery":"EXTERNAL"},"title":"Command Injection in Veeder-Root TLS4B Automatic Tank Gauge System","x_generator":{"engine":"Vulnogram 0.4.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-10-23T20:29:14.855795Z","id":"CVE-2025-58428","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-10-23T20:29:27.332Z"}}]}}