{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-7353","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","dateReserved":"2025-07-08T12:24:08.365Z","datePublished":"2025-08-14T13:23:26.940Z","dateUpdated":"2026-02-26T17:48:36.010Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"1756-EN2T/D","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"Version 11.004 or below"}]},{"defaultStatus":"unaffected","product":"1756-EN2F/C","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"Version 11.004 or below"}]},{"defaultStatus":"unaffected","product":"1756-EN2TR/C","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"Version 11.004 or below"}]},{"defaultStatus":"unaffected","product":"1756-EN3TR/B","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"Version 11.004 or below"}]},{"defaultStatus":"unaffected","product":"1756-EN2TP/A","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"Version 11.004 or below"}]}],"datePublic":"2025-08-14T13:11:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow. &nbsp;</p><br>"}],"value":"A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1188","description":"CWE-1188: Initialization of a Resource with an Insecure Default","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2025-08-14T13:49:37.413Z"},"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1732.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">12.001 and later</span><br>"}],"value":"12.001 and later"}],"source":{"advisory":"SD1732","discovery":"INTERNAL"},"title":"Rockwell Automation ControlLogix® Ethernet Remote Code Execution Vulnerability","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2025-7353","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2025-08-15T03:55:59.205927Z"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-02-26T17:48:36.010Z"}}]}}