{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-7357","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2025-07-08T14:32:29.576Z","datePublished":"2025-07-16T15:56:33.623Z","dateUpdated":"2025-07-18T14:38:53.584Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"IC48A EV Charger","vendor":"LITEON","versions":[{"lessThan":"01.00.19r","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"IC80A EV Charger","vendor":"LITEON","versions":[{"lessThan":"01.01.12e","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Murat Sagdullaev of Electrada"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.</p><br>"}],"value":"LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-256","description":"CWE-256 Plaintext Storage of a Password","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2025-07-16T15:56:33.623Z"},"references":[{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-196-03"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>LITEON has released the following firmware versions for the following EV chargers:</p><ul><li>LITEON IC48A: Firmware versions 01.00.20h</li><li>LITEON IC80A: Firmware versions 01.01.13m</li></ul><p>For more information, contact <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.liteon.com/en/contact/contact-us\">LITEON</a>.</p>\n\n<br>"}],"value":"LITEON has released the following firmware versions for the following EV chargers:\n\n  *  LITEON IC48A: Firmware versions 01.00.20h\n  *  LITEON IC80A: Firmware versions 01.01.13m\n\n\nFor more information, contact  LITEON https://www.liteon.com/en/contact/contact-us ."}],"source":{"discovery":"UNKNOWN"},"title":"Plaintext Storage of a Password in LITEON IC48A and IC80A EV Chargers","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-07-18T14:38:46.980127Z","id":"CVE-2025-7357","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-07-18T14:38:53.584Z"}}]}}