{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-7773","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","dateReserved":"2025-07-17T18:26:16.808Z","datePublished":"2025-08-14T13:52:35.800Z","dateUpdated":"2025-08-14T14:00:41.556Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"5032-CFGB16M12P5DR","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"1.011"}]},{"defaultStatus":"unaffected","product":"5032-CFGB16M12DR","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"1.011"}]},{"defaultStatus":"unaffected","product":"5032-CFGB16M12M12LDR","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"1.011"}]}],"datePublic":"2025-08-14T13:11:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>A security issue exists within the 5032 16pt Digital Configurable module’s web server. The web server’s session number increments at an interval that correlates to the last two consecutive sign in session interval, making it predictable. &nbsp;</p><br>\n\n<br>\n\n<br>\n\n<br>\n\n<br>"}],"value":"A security issue exists within the 5032 16pt Digital Configurable module’s web server. The web server’s session number increments at an interval that correlates to the last two consecutive sign in session interval, making it predictable."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.8,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"LOW","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-863","description":"CWE-863: Incorrect Authorization","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2025-08-14T13:52:35.800Z"},"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1733.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"1.012 or later"}],"value":"1.012 or later"}],"source":{"advisory":"SD1733","discovery":"INTERNAL"},"title":"Rockwell Automation ArmorBlock 5000 I/O – Web Server Vulnerabilities","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-08-14T14:00:24.172420Z","id":"CVE-2025-7773","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-08-14T14:00:41.556Z"}}]}}