{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-84400","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2026-09-10T15:00:49.635Z","datePublished":"2026-09-18T16:10:28.768Z","dateUpdated":"2026-09-19T14:11:43.861Z"},"containers":{"cna":{"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2026-09-18T16:10:28.768Z"},"title":"CareCam CM2507 Missing Authentication for Critical Function","problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-306","description":"CWE-306","type":"CWE"}]}],"affected":[{"vendor":"CareCam","product":"HMT.CM2507 Firmware","versions":[{"status":"affected","version":"v251211.1507"}],"defaultStatus":"affected"}],"descriptions":[{"lang":"en","value":"CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.","supportingMedia":[{"type":"text/html","base64":false,"value":"CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access."}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE","baseSeverity":"LOW","baseScore":3.1,"vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N"}},{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"LOW","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"LOW","baseScore":2.3,"vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N"}}],"workarounds":[{"lang":"en","value":"CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.","supportingMedia":[{"type":"text/html","base64":false,"value":"CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information."}]}],"credits":[{"lang":"en","value":"Ben Law reported this vulnerability to CISA.","type":"finder"}],"source":{"advisory":"ICSA-26-258-08","discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 1.0.5"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2026-84400","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2026-09-19T13:44:30.475992Z"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-09-19T14:11:43.861Z"}}]}}