{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-85544","assignerOrgId":"da451dce-859b-4e51-8b87-9c8b60d19b32","state":"PUBLISHED","assignerShortName":"hikvision","dateReserved":"2026-09-04T09:24:07.712Z","datePublished":"2026-09-10T12:26:00.396Z","dateUpdated":"2026-09-18T09:39:16.889Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Some Hikvision intercom products utilize an immutable factory value which should be obtained from local network or physical interaction with the device within their main card, which may allow attackers to forge a legitimate main card, thereby gaining the permission to issue cards."}],"affected":[{"vendor":"Hikvision","product":"DS-KV9503","versions":[{"version":"V2.3.13 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV6113","versions":[{"version":"V3.7.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV6103","versions":[{"version":"V3.7.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV6133","versions":[{"version":"V3.7.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV8113","versions":[{"version":"V3.7.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV8213","versions":[{"version":"V3.7.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV8413","versions":[{"version":"V3.7.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KD8003","versions":[{"version":"V3.7.1 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KD8005","versions":[{"version":"V3.10.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV6114","versions":[{"version":"V3.9.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV6124","versions":[{"version":"V3.9.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV6134","versions":[{"version":"V3.9.0 and the versions prior to it","status":"affected"}]},{"vendor":"Hikvision","product":"DS-KV8114","versions":[{"version":"V3.11.0 and the versions prior to it","status":"affected"}]}],"references":[{"url":"https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-intercom-products"}],"credits":[{"lang":"en","value":"Filipe Moreira","type":"finder"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N"}}],"problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-798","lang":"en","description":"CWE-798 Use of Hard-coded Credentials"}]}],"x_generator":{"engine":"cveClient/1.0.15"},"providerMetadata":{"orgId":"da451dce-859b-4e51-8b87-9c8b60d19b32","shortName":"hikvision","dateUpdated":"2026-09-18T09:39:16.889Z"}},"adp":[{"problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-1310","lang":"en","description":"CWE-1310 Missing Ability to Patch ROM Code"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-09-10T14:51:42.740079Z","id":"CVE-2026-85544","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-09-10T14:52:28.338Z"}}]}}